this post was submitted on 18 Oct 2025
290 points (96.8% liked)

196

4641 readers
1898 users here now

Community Rules

You must post before you leave

Be nice. Assume others have good intent (within reason).

Block or ignore posts, comments, and users that irritate you in some way rather than engaging. Report if they are actually breaking community rules.

Use content warnings and/or mark as NSFW when appropriate. Most posts with content warnings likely need to be marked NSFW.

Most 196 posts are memes, shitposts, cute images, or even just recent things that happened, etc. There is no real theme, but try to avoid posts that are very inflammatory, offensive, very low quality, or very "off topic".

Bigotry is not allowed, this includes (but is not limited to): Homophobia, Transphobia, Racism, Sexism, Abelism, Classism, or discrimination based on things like Ethnicity, Nationality, Language, or Religion.

Avoid shilling for corporations, posting advertisements, or promoting exploitation of workers.

Proselytization, support, or defense of authoritarianism is not welcome. This includes but is not limited to: imperialism, nationalism, genocide denial, ethnic or racial supremacy, fascism, Nazism, Marxism-Leninism, Maoism, etc.

Avoid AI generated content.

Avoid misinformation.

Avoid incomprehensible posts.

No threats or personal attacks.

No spam.

Moderator Guidelines

Moderator Guidelines

  • Don’t be mean to users. Be gentle or neutral.
  • Most moderator actions which have a modlog message should include your username.
  • When in doubt about whether or not a user is problematic, send them a DM.
  • Don’t waste time debating/arguing with problematic users.
  • Assume the best, but don’t tolerate sealioning/just asking questions/concern trolling.
  • Ask another mod to take over cases you struggle with, if you get tired, or when things get personal.
  • Ask the other mods for advice when things get complicated.
  • Share everything you do in the mod matrix, both so several mods aren't unknowingly handling the same issues, but also so you can receive feedback on what you intend to do.
  • Don't rush mod actions. If a case doesn't need to be handled right away, consider taking a short break before getting to it. This is to say, cool down and make room for feedback.
  • Don’t perform too much moderation in the comments, except if you want a verdict to be public or to ask people to dial a convo down/stop. Single comment warnings are okay.
  • Send users concise DMs about verdicts about them, such as bans etc, except in cases where it is clear we don’t want them at all, such as obvious transphobes. No need to notify someone they haven’t been banned of course.
  • Explain to a user why their behavior is problematic and how it is distressing others rather than engage with whatever they are saying. Ask them to avoid this in the future and send them packing if they do not comply.
  • First warn users, then temp ban them, then finally perma ban them when they break the rules or act inappropriately. Skip steps if necessary.
  • Use neutral statements like “this statement can be considered transphobic” rather than “you are being transphobic”.
  • No large decisions or actions without community input (polls or meta posts f.ex.).
  • Large internal decisions (such as ousting a mod) might require a vote, needing more than 50% of the votes to pass. Also consider asking the community for feedback.
  • Remember you are a voluntary moderator. You don’t get paid. Take a break when you need one. Perhaps ask another moderator to step in if necessary.

founded 9 months ago
MODERATORS
 

You may not like it but this is what the perfect mains plug looks like /j

you are viewing a single comment's thread
view the rest of the comments
[–] rbn@sopuli.xyz 5 points 1 day ago (2 children)

From all I read so far, the UK plugs are indeed superior to EU and most other plugs. Still I feel like I'd miss the option to plug things upside down.

[–] purplemonkeymad@programming.dev 10 points 1 day ago (2 children)

Live and neutral are typically not interchangeable. fuses should be on the live cables so that over current is stopped on the way in. Plugging in the wrong way means that a blown fuse might stop current, but the device could still be at live voltages and be dangerous.

[–] fullsquare@awful.systems 11 points 1 day ago (4 children)

that's why you put fuses in central fuse box, not in the plug. appliances should be designed in such a way that it shouldn't be a problem. nobody else does this because it's not necessary if your installation is sanely built

[–] WALLACE@feddit.uk 2 points 19 hours ago (1 children)

The central fuse boxes only protect the house wiring. You need a lower rated fuse for individual devices. That 30A central fuse ain't gonna protect the wiring inside your 6A lamp.

[–] fullsquare@awful.systems 1 points 14 hours ago

yeah that's what separate fuses for separate branches of circuit are for, all in one central box because where else are these supposed to be. if your lamp is wired with 6A-rated wire then that branch should be fused with 6A fuse, which on its own is unhinged because usually much thicker wires are used anyway

[–] witty_username@feddit.nl 9 points 1 day ago (2 children)

This is the reason why uk home electrical wiring has fuses everywhere. It is a safety measure that mitigates other problems like poor design and bad installation practices

[–] sauerkrautsaul@lemmus.org 3 points 1 day ago

its not, it was put into place due to copper shortages during ww2

[–] fullsquare@awful.systems 2 points 1 day ago

more like papers over poor design informed by ww2 shortages

[–] prex@aussie.zone 6 points 1 day ago (1 children)

A fuse/breaker at the fuse box needs the current capacity for all, or at least most devices on at the same time. The individual fuses can be rated much lower.

[–] fullsquare@awful.systems 4 points 1 day ago* (last edited 1 day ago) (1 children)

uk fuse in fuse box can't be sized properly because old uk installations used ring circuits in order to save copper during ww2 shortages, everybody else has this problem sorted out by now (initially by using aluminum wiring, or waiting for more copper). modern wiring is arranged in star-type topology with a few outlets per leg, and it can be fused properly, but the far out parts of circuit don't transmit power at all times which is why it was looked down upon during shortages

example would be 16A circuit that has 5-10 16A outlets, has wires suitable to carry 16A and 16A fuse. it's okay because you're not expected to draw full power at all outlets at the same time, and most of the time much less than that. if you do and you know it in advance you're expected to split it over more circuits, or make it bigger. uk ring circuit would have wires that carry only 8A in each direction, and fused 16A. it can fail in a way where one side disconnects, but the other side becomes overloaded. plug fuses are for protection of these shitty circuits from shortcircuit in appliance

[–] prex@aussie.zone 1 points 1 day ago (2 children)

Do UK ring circuits rely on a single breaker at the fusebox? I assumed that they would have a breaker for each leg of the ring (8A + 8A in your example).
That sounds really dangerous as a cut ring would be fused at double the current capacity of the wire. Would the wire in your example be rated at 8A or 16A?
I have little to no knowledge of the UK power setup but have heard that its meant to be pretty safe. What am I missing?

[–] fullsquare@awful.systems 1 points 14 hours ago* (last edited 14 hours ago)

you're not missing anything, it's an unhinged tradeoff that you do because you need to conserve copper for brass casings because nazis are in calais, there's zero reason to do this today. apparently it's still allowed in uk for some unthinkable reason but i haven't heard of it anywhere else. yes, single fuse *per ring is used, rated at double what it would be in star/radial circuit

you don't even need a fault, sufficient asymmetry in ring geometry or load distribution already will cause this problem

[–] WALLACE@feddit.uk 1 points 19 hours ago

60yr old house in the UK, we have one breaker per socket circuit for example. It uses 2.5mm wire which can handle 30A, so that would be the max recommended fuse rating at the breaker. That way it's still protected if there is a break in the circuit anywhere.

We also have a separate lighting circuit with 1.5mm wire and a lower breaker fuse rating.

It can lead to some annoying fuckery though. I recently updated a ceiling light and was frustrated at why it wouldn't switch on after triple checking every connection. Had to get out a multimeter and investigate all over the house. Turns out at some point in the past a previous homeowner had not bothered to connect the neutral wire back to the fusebox at an entirely different ceiling light, leaving the neutral floating. It was sitting at 110V rather than zero. Somehow it was OK to do that with old lights.

[–] piccolo@sh.itjust.works 2 points 1 day ago* (last edited 1 day ago)

appliances should be designed in such a way

Such as... putting a fuse in the appliance making repairs more difficult. A breaker box stops extreme overcurrents, but a measly 0.5 amps could still cause a fire.

[–] rtxn@lemmy.world 5 points 1 day ago

Polarized live/neutral is still insane to me. All it takes is one cheap electrician or overconfident DIY to introduce a potentially lethal false sense of security.

[–] bamboo@lemmy.blahaj.zone 5 points 1 day ago

The rest of the world has chose your own adventure plugs